It’s essential for your business to consider the right ETO Sterilizer Equipment to purchase because, in the event you manufacture medical devices or medicines, then low-temperature sterilization will be required. The decision of choosing between the single and double door sterilizers will depend upon your production line, volume and segregation requirements.
Single door sterilizers may be used for loading and unloading the products. Double door sterilizers may be used for separate loading and unloading. Krishna Engineering makes and sells single and double door ETO sterilizers having hinged or sliding doors according to your requirements.
What’s a Single Door ETO Steriliser?
A single door ETO steriliser is a chamber that uses Ethylene Oxide gas to sterilise compatible products. It can be loaded and unloaded using the same door. This would be suitable for facilities who want to use one door.
- Medical Device Manufacturing – Sterilise compatible medical devices and disposables.
- Pharmaceutical – Sterilise compatible products and materials by using validated sterilization techniques.
- Laboratories – Sterilize selected heat-sensitive instruments and materials.
- Specialist Industrial – Sterilize compatible products which do not suit specific types of sterilization.
Only one door would be sufficient in cases where there is limited space or segregation of loading and unloading is not required.
What’s a Double Door ETO Steriliser?
Double door sterilisers have two doors allowing them to have separate loading and unloading areas. This can help to create a more organised workflow.
May be useful for medical device manufacturers, pharmaceutical manufacturers and other facilities that will incorporate sterilisation into their production process.
Key factors to consider:
- Segregation – You can load and unload with separate areas.
- Workflow – Helps to create a more defined workflow.
- Facility integration – Can be used in facilities that require segregation.
- Door interlocking – Helps to prevent both doors opening at the same time.
A double door does not necessarily mean it will be sterile. The design, workflow, validated process and correct controls need to be in place.
Single Door vs Double Door
Your choice will depend on how your products are moved through your facility.
Comparison | Single Door ETO Steriliser | Double Door ETO Steriliser |
Number of Doors | 1 door | 2 doors (usually opposite sides) |
Loading/Unloading | Same door | Separate doors |
Workflow | Suitable for simpler workflows | More defined workflow |
Space requirements | 1 side needs to have access | Both sides need to have access
|
Facility integration | Suitable for facilities who don’t need to segregate loading and unloading | Can be used for facilities who have defined areas for loading/unloading |
Installation | May be easier to install if there is limited access | Both sides need to be coordinated |
Best for | Facilities with one access workflow | Facilities who need to segregate loading/unloading. |
Your choice should be based on your facility design, workflow, processes and features available.
Things to consider
1. Facility Design & Space
You’ll need to consider the space available for installation, door access and product movement. A single door steriliser will require access to one side of the chamber. A double door steriliser will require access to both sides.
With a double door steriliser, ensure the areas around it are planned to allow for safe loading, unloading, staff movement and maintenance.
2. Batch Size & Volume
This will depend on the product size, batch size, packaging and how much you expect to produce. Whilst a higher volume may affect your choice of chamber size, it doesn’t necessarily mean you’ll need a double door.
Check how many batches you’ll have, how the products will be moved and what you need to get the job done. The steriliser chambers can be designed to meet your requirements. Contact Krishna Engineering to find out what sizes are available.
3. Workflow
Consider how your products will be moved. If you’re loading and unloading in the same area then a single door steriliser may be best for you. If you have separate areas for products to go in and out of then a double door may be something to consider.
Ensure there are clear indications of where the products are in the process, how they are being moved and controls in place to avoid confusion.
4. Safety & Door Interlocking
As the steriliser uses Ethylene Oxide Gas, this is a hazardous gas and therefore should be handled correctly. Ensure the steriliser has the correct safety measures.
Ask your manufacturer about door locking, interlocking, pressure monitoring, alarms, gas leak detection, gas removal and aeration. With a double door steriliser, ensure you know how the interlocking works to stop unsafe door opening and how it will integrate with your processes.
5. Automation
In order to maintain sterilisation consistency, it’s necessary to control and monitor the parameters of the process you have validated. These could be automatically controlled by the machine for you depending on the type of autoclave that you have.
Before purchasing, check what controls, alarms, cycle recording and monitoring are available. Ask about the documentation available.
6. Installation, Maintenance & Support
Ensure the steriliser can be installed in your facility. Ask about installation requirements, staff training, spares, service and preventative maintenance.
With a double door steriliser ensure you can access both sides. A suitable installation will allow for efficient operation.
How to choose the right ETO Steriliser for your facility
Checklist:
Requirement | What to Check |
Product Compatibility | Materials, Packaging & ETO Sterilisation suitability |
Batch Size | Product Size, Quantity & Expected Volume |
Workflow | Loading/Unloading Segregation
|
Space | Door Access, Staff Movement & Maintenance |
Safety | Door Interlocking, Alarms, Gas & Aeration |
Control | Monitoring, Automation & Cycle Recording |
Compliance | Standards & Validation Documentation |
Support | Installation, Training, Maintenance & Spares |
If you need to segregate loading and unloading areas then a Double Door ETO Steriliser may be best for you. If you can use a single access point then a single door may be sufficient. Contact Krishna Engineering to discuss your facility, batch size and processes.
Why Choose Krishna Engineering?
Krishna Engineering is a manufacturer and exporter of ETO sterilisers based in Ahmedabad, Gujarat. We were set up in 2000 and offer double and single door ETO sterilisers. We also offer hinged or sliding doors depending on your requirements.
When considering Krishna Engineering for your facility consider:
Configuration
Ask about the door configuration and chamber design to suit your workflow.
Automation
Ask about the controls and monitoring available.
Custom Sizes
Ensure the chamber size and capacity is correct for your products.
Safety
Ask about the door locking, gas and other safety features available.
Installation
Ensure you know how the steriliser will be installed, documented, maintained and after-sales support.
Ask for a detailed technical quote to ensure the configuration, chamber size, safety features, documentation and compliance are clear.
FAQ
It depends on your requirements. A double door may be useful if you need to segregate loading and unloading. A single door may be suitable for simpler workflows.
Generally, yes. Both sides need to have correct access and space. The exact space will depend on the size of the equipment, door type and installation.
ETO sterilisation can be used to sterilise compatible medical devices, pharmaceutical products and chosen heat sensitive materials. It will depend on the material, packaging and validated process.
Ask about door locking, interlocking, pressure monitoring, alarms, gas leak detection, gas removal and aeration. This will depend on the design and safety requirements.
This will provide documented evidence that your sterilisation process will consistently give you the desired outcome for the product and load. Simply choosing the correct equipment will not show that it will be effective.
Conclusion
Whether to choose one door or two will be influenced by your facility’s design, the batch requirement, the process of moving and handling of the product. It’s possible that one door would work well for a facility where the loading and unloading happens from the same place. Two doors would be more effective to help with creating a flow within the system. At Krishna Engineering, we have a number of options when it comes to doors.
Contact us if you require a Double Door ETO Steriliser.